Off-Grid Solar Battery Bank Calculator

An off grid solar battery calculator has to think in days, not hours, because there is no grid to fall back on when the sky stays grey. This version sizes the bank from your daily energy use in units (kWh) and the number of days of autonomy you want to cover, then applies the system voltage and depth of discharge. It is free, needs no signup and nothing you type is stored.

FreeNo signupNothing uploaded or stored

What the battery must do

Off grid banks are sized in days of autonomy, not hours. Enter your daily units and the number of cloudy days to cover.

Average units used per day

Consecutive poor-sun days to cover

Battery chemistry and voltage

Match your inverter's battery voltage

Sets the usable depth of discharge

Lithium ≈ 0.85, lead-acid ≈ 0.5. Editable from your datasheet.

How many batteries?

From the label of the model you plan to buy

Battery capacity needed

0 Ah

at 48 V, lithium DoD 0.85

Bank size

0.00 kWh

0.00 kWh usable ÷ 0.85

Usable energy required

0.00 kWh

0.00 kWh × 2 days

Batteries to buy

-

Enter one battery's Ah above

Formula: Ah = daily kWh × 1,000 × days ÷ system V ÷ DoD. Series count = system V ÷ battery V; parallel strings = ⌈required Ah ÷ battery Ah⌉.

How to use the off-grid solar battery bank calculator

  1. Enter your daily energy consumption in units (kWh). Add up each appliance with the home load calculator or read an average day from your meter.
  2. Choose the days of autonomy: how many consecutive days of poor sun the bank must carry you through without the array recharging it.
  3. Set the system voltage. Off grid homes usually run 48V banks, which keep the amp-hours and cable sizes manageable.
  4. Pick the chemistry. Lithium lets you use most of the capacity; lead acid needs roughly double the rated amp-hours for the same stored energy.
  5. Read the bank size in kWh and Ah, then check the solar system size calculator to make sure the array can refill that bank in one good day.

What to include

  • A daily consumption figure measured over a real week, including the fridge and water pump cycles
  • A seasonal view: winter days are shorter and cloudier, so size for the worst month you will occupy the property
  • The number of autonomy days you are willing to pay for, often two to three for a home and one for a weekend cabin
  • The system voltage your inverter and charge controller share
  • The chemistry and its depth of discharge from the datasheet
  • A backup generator plan for the rare run of bad weather that exceeds the autonomy you chose
  • Room for growth, since off grid loads tend to increase once the system exists

Days of autonomy: the number that drives everything

The formula becomes Ah = (daily Wh × days of autonomy) ÷ voltage ÷ depth of discharge. Every extra day of autonomy adds a whole day of storage, so the choice has more effect on cost than any other input. One day covers a single overcast day; two to three days is common for a full-time home; more than that is usually better handled by a small generator than by more batteries.

Say you type 8 units a day, 2 days of autonomy, 48V and lithium. That is 16,000 Wh, which is about 333 Ah at 48V, and at 0.85 depth of discharge the bank comes to roughly 392 Ah, or a 19 kWh class system. The same inputs with lead acid at 0.5 would need around 667 Ah. Seeing those two figures side by side usually settles the chemistry question.

Matching the battery to the array

A bank that can store two days of energy is useless if the panels can only put back half a day. After sizing the battery here, go to the system size calculator and confirm the array produces your daily units plus enough surplus to recharge the bank after a bad spell. Rule of thumb: the array should be able to refill the usable bank capacity in one or two good sun days, otherwise you will slowly run short in winter.

Frequently asked questions

How many days of autonomy should I choose?

For a full-time off grid home, two to three days is a common compromise between cost and comfort. For a weekend cabin, one day is often enough because you can leave if the weather turns.

Should I size for summer or winter?

Winter, if you live there year round. Days are shorter and loads are often higher, so the bank and the array both need to cover the worst month, not the average.

Can I size the battery in kWh instead of Ah?

Yes. The calculator shows both. Many off grid suppliers quote lithium storage in kWh, and the kWh figure is independent of voltage, so it is the easier number to compare.

What if my daily usage varies a lot?

Use the highest typical day rather than the average. A bank sized for the average will leave you short on the days you use the most, which are usually the cold or hot ones.

Is this tool really free and private?

Yes. There is no account, no payment and no server-side processing. The numbers stay in your browser.