Skip to content

Lead Acid Solar Battery Calculator

Lead acid batteries, whether flooded, tubular, AGM or gel, are still the most common choice for home inverters and smaller solar systems because of the lower upfront cost per amp-hour. This lead acid solar battery calculator sizes the bank with a 50 percent depth of discharge, so the number you get is what you need to buy, not what you need to drain. Free, no account, runs in your browser.

FreeNo signupNothing uploaded or stored

What the battery must do

Total watts of everything on the battery at once

How long the load must run

Battery chemistry and voltage

Match your inverter's battery voltage

Sets the usable depth of discharge

Lithium ≈ 0.85, lead-acid ≈ 0.5. Editable from your datasheet.

How many batteries?

From the label of the model you plan to buy

Battery capacity needed

0 Ah

at 12 V, lead-acid DoD 0.5

Bank size

0.00 kWh

0.00 kWh usable ÷ 0.5

Usable energy required

0.00 kWh

0 W × 4 h

Batteries to buy

-

Enter one battery's Ah above

Formula: Ah = load W × hours ÷ system V ÷ DoD. Series count = system V ÷ battery V; parallel strings = ⌈required Ah ÷ battery Ah⌉.

How to use the lead acid solar battery calculator

  1. Enter the load in watts you want to run from the batteries during an outage, counting every fan, light and router that stays on.
  2. Type the backup hours. Lead acid banks for homes are often sized for a few hours of load-shedding rather than overnight.
  3. Choose the system voltage. Most lead acid home inverters are 12V with one battery or 24V with two in series.
  4. Keep the chemistry on lead acid so the tool halves the label capacity to the usable share, then read the amp-hours.
  5. Divide the result by the Ah rating of your chosen battery, round up, and check that the count matches your inverter's voltage.

What to include

  • A load figure that includes the inverter's own idle draw if you know it
  • Backup hours based on your typical outage, not the longest one you can remember
  • The inverter voltage so the series string adds up correctly: two 12V batteries for 24V, four for 48V
  • The battery's 20-hour (C20) amp-hour rating, which is the one usually printed on the label
  • Space and ventilation for flooded batteries, which release gas while charging
  • A plan to replace the whole string together, since mixing old and new lead acid units shortens the life of both

Why a lead acid bank needs twice the rated capacity

A lead acid battery that is routinely discharged below half of its rating ages fast: plates sulphate, capacity drops and the bank fails years early. Treating 50 percent as the floor is the standard rule for daily cycling, so the calculator divides your energy need by 0.5. The formula is Ah = (watts × hours) ÷ voltage ÷ 0.5, which is the same as doubling the amp-hours a lithium bank would need.

Say you type 400 W for 4 hours on a 12V inverter. That is 1,600 Wh, which is about 133 Ah at 12V, and dividing by 0.5 gives roughly 267 Ah. In practice you would look at two 150 Ah batteries in parallel, or move to a 24V inverter and put them in series. The tool shows the watt-hours too, so you can sanity-check against a battery's label.

Tubular, AGM or gel: does the choice change the maths?

Not the sizing formula. All three are lead acid chemistries with roughly the same usable depth of discharge, so the amp-hours come out the same. They differ in maintenance, tolerance to heat and deep cycling, and in how fast they can be charged. Tall tubular batteries are popular for daily cycling in hot climates, AGM and gel are sealed and need no topping up. Pick the type on those grounds, then size it here.

Frequently asked questions

How many 200Ah batteries do I need?

Run the calculator with your load, hours and inverter voltage, then divide the amp-hour result by 200 and round up. For a 24V inverter the batteries go in pairs, so round up to an even number.

Can I enter a different depth of discharge for lead acid?

Yes. The default is 0.5, but if you only cycle occasionally and want to use more of the capacity, or want to be gentler for a longer life, type your own value.

Does the calculator work for a car battery?

The maths is the same, but car batteries are built for short bursts of high current, not deep cycling, and will wear out quickly as a backup battery. Use a deep-cycle type.

What is the difference between C10 and C20 ratings?

They state capacity at different discharge speeds. A battery delivers slightly fewer amp-hours when drained faster, so the C10 figure is lower than C20 for the same battery. Enter whichever one is on the label and treat the result as approximate.

Will the site keep my figures?

No. Nothing is uploaded or saved on a server. The calculation happens in your browser and the page forgets your inputs when you leave.