Skip to content

Off-Grid Solar System Size Calculator

An off-grid solar system size calculator has to do more than count panels, because there is no grid to fall back on. This version sizes the array from your daily energy, the inverter from your peak load, and then introduces battery autonomy days, the number of cloudy days the bank must carry you without meaningful charge. It is written for cabins, farms, remote homes and sites where connecting to the grid is not an option.

FreeNo signupNothing uploaded or stored

Your consumption

Average energy used per day

Monthly equivalent

0 units

daily kWh × 30

Site and equipment

For off-grid use, enter the peak sun hours of your worst month rather than the annual average.

Equivalent hours of full sun. See the table below.

0.78 absorbs inverter, wiring, dust and heat losses

Rating printed on the panel datasheet

Largest load that runs at the same time

1.25 leaves 25% margin for surges and heat

Battery (optional)

Sets the usable depth of discharge

Lithium ≈ 0.85, lead-acid ≈ 0.5

Cloudy days the bank must cover with no sun

Typical peak sun hours by region

Peak sun hours (PSH) are the equivalent hours per day of full 1,000 W/m² sunshine. These are rough annual averages: use a local figure or your worst month for off-grid sizing. No prices or tariffs are involved.

RegionPSH / dayNote
Pakistan (Punjab, Sindh, Balochistan)5.0 – 5.5Northern valleys and the Karachi coast are nearer 4.5 – 5
India (most states)4.5 – 5.5Lower on the monsoon coast and in the north-east
Bangladesh / Sri Lanka / Nepal plains4.0 – 5.0Dip during the monsoon months
Gulf (UAE, Saudi Arabia, Qatar, Oman)5.5 – 6.5Dust can reduce output without changing PSH
Nigeria north and middle belt5.5 – 6.0Humid south (Lagos, Port Harcourt) is 4.0 – 4.5
Kenya / East Africa5.0 – 6.0High-altitude sites are at the upper end
South Africa interior5.5 – 6.0Durban and the Cape coast are closer to 5.0
Philippines / Indonesia / Malaysia4.0 – 5.0Large seasonal dip in the rainy season
Australia (most cities)4.5 – 6.0Hobart and Melbourne are at the lower end
US Southwest5.5 – 6.5Arizona, Nevada, southern California
US Northeast / Midwest / Canada3.5 – 4.5Winter months can fall below 2.5
Southern Europe / Turkey / Egypt4.0 – 5.5Mediterranean coast
UK, Ireland, Northern Europe2.5 – 3.5Annual average; winter is much lower

Recommended array size

0.00 kW

0.00 kWh/day ÷ (4.0 h × 0.78)

Number of panels

0

550 W each → 0.00 kW installed

Inverter size

-

Enter your peak simultaneous load

Monthly production needed

0 units

0.00 kWh per day

Battery bank

0.00 kWh

0.00 kWh × 2 days ÷ 0.85 DoD

Capacity at bank voltage

0 Ah

0.00 kWh × 1,000 ÷ 48 V

Formula: array kW = daily kWh ÷ (peak sun hours × efficiency); panels = ⌈array W ÷ panel W⌉; inverter kW = peak load × 1.25; battery kWh = stored energy ÷ DoD. On-grid inverters are usually rated close to the array kW; hybrid and off-grid inverters must carry the peak load alone.

How to use the off-grid solar system size calculator

  1. Build a daily kWh figure from an appliance list rather than a bill, since off-grid homes rarely have a meter to copy from.
  2. Enter peak sun hours for the site, then consider using the worst-month figure instead of the annual average, because an off-grid system has to survive winter.
  3. Enter the largest load you will run at once, including motor start-up, and the tool suggests an inverter rating with headroom.
  4. Set the number of autonomy days you want, usually two or three, and choose lithium or lead-acid so the depth-of-discharge factor is right.
  5. Read the array kW, panel count, inverter kW and the battery capacity implied by your autonomy setting, then take all four to an installer.

What to include

  • A complete appliance list with watts and daily run hours
  • Worst-month peak sun hours rather than the annual average
  • Peak simultaneous load including compressor and pump surges
  • Battery chemistry, since lithium and lead-acid use very different depth of discharge
  • System voltage, commonly 12, 24 or 48 V, for the battery capacity calculation
  • Autonomy days you want to cover without sun
  • A backup generator plan for the rare long stretch of cloud

What changes when there is no grid to lean on

A grid-tied home can size to the annual average because the utility fills every gap. An off-grid home has no such cushion, so the array must produce enough on a poor winter day and the battery must hold enough to ride through cloudy stretches. That is why this calculator asks you to think in worst-month sun hours and autonomy days. If December gives your site 3 peak sun hours while the annual average is 4.5, size to 3. The system will then overproduce in summer, which is harmless; the alternative is running out of power in winter, which is not.

Battery autonomy days is the number of consecutive days the bank can supply your full daily load with little or no sun. Two days is a common minimum for a home, three or more for sites with long overcast spells or where the consequences of running out are serious. The capacity is daily watt-hours multiplied by autonomy days, divided by battery voltage and then by depth of discharge. Lithium banks can be drawn to roughly 0.8 or 0.9 of capacity, lead-acid to about 0.5, so lead-acid banks end up nearly twice the nominal size for the same usable energy.

Keeping an off-grid system small enough to afford

The cheapest kilowatt-hour is the one you do not use. Before sizing, go through the appliance list and look for loads that can move to gas, propane or sunlight hours. Water heating, cooking and space heating are the usual candidates, because they are large and run when the sun is down. Shifting a washing machine or a water pump to midday lets the panels power it directly without cycling the battery. Each kilowatt-hour removed from the night-time load shrinks the battery, the inverter and often the array.

Frequently asked questions

How many days of battery autonomy should I plan for?

Two days suits most homes in sunny regions. Go to three or four if winters are long and grey or if a power failure would spoil food, stop a water pump or affect medical equipment.

Should I use annual or worst-month sun hours for off-grid?

Worst month. An off-grid system has to work in its hardest month, so size to that and accept surplus the rest of the year.

Lithium or lead-acid for an off-grid bank?

Lithium allows deeper discharge, so the bank is smaller for the same usable energy and tolerates daily cycling better. Lead-acid still works, but size it to about half its nominal capacity being usable.

Why is my inverter so much bigger than my average load?

Because the inverter must handle the moment everything starts at once, not the average. The tool multiplies your peak load by 1.25; if a well pump or compressor is the biggest item, check its surge rating too.

Do I still need a generator if the system is sized properly?

Many off-grid owners keep a small generator for the rare week of continuous cloud, because sizing the battery for that case would make it enormous. Treat it as insurance rather than a daily tool.

Is this off-grid calculator free to use?

Yes. There is no signup, nothing is saved, and the entire calculation runs in your browser.