How to use the hybrid solar system size calculator
- Enter your average monthly units. The array is sized to the annual average because the grid still fills seasonal gaps on a hybrid system.
- Set peak sun hours for your area and keep the efficiency factor at its default unless you have a site survey.
- List the appliances you want to keep running during an outage and enter their combined watts as the peak load, since the hybrid inverter must carry that on its own.
- Choose a panel wattage and check the panel count against the roof, then decide how many hours of outage the battery should bridge.
- Read the array and inverter figures and continue to the battery calculator for the exact storage capacity.
What to include
- Monthly units for the array size, averaged across the year
- A short list of essential loads for the backup circuit, with their watts
- Hours of outage per day that the battery must cover
- Peak sun hours for the array, from the regional hint or a solar map
- Battery chemistry, as lithium allows deeper daily cycling than lead-acid
- Whether the inverter should charge the battery from the grid as well as from solar
- Large loads to keep off the backup circuit, such as ovens, geysers and heaters
Hybrid sizing: the array covers the bill, the battery covers the gaps
A hybrid system has two sizing problems that are easy to confuse. The array is sized like a grid-tied system, to produce roughly the energy the house uses across the year. The battery and inverter are sized to the essential loads you want during an outage and for how long. Keeping these separate avoids the common mistake of buying an enormous battery to match a large array, or a tiny inverter that trips the moment the fridge and pump start together during a cut.
For the backup side, start with the essentials: lighting, refrigerator, internet router, a few plug points and perhaps one fan or a small air conditioner. Add their watts and that becomes the peak load the inverter must handle alone, multiplied by 1.25 for headroom. Then multiply the average draw of those loads by the outage hours to get the watt-hours the battery needs, and divide by voltage and depth of discharge. Lithium can be cycled to roughly 0.8 or 0.9 of its capacity; lead-acid to about 0.5.
When hybrid is the right choice over on-grid or off-grid
Hybrid makes sense when the grid is present but unreliable, or when you want the savings of exporting surplus by day and the comfort of backup by night. It costs more than a plain grid-tied system because of the battery and the more capable inverter, but far less than going fully off-grid, because the grid still handles bad weather and long winters. If outages are rare, on-grid is simpler. If there is no grid at all, the off-grid calculator with its autonomy-days setting is the right tool.
Frequently asked questions
Does a hybrid system need the same size battery as an off-grid one?
Usually much smaller. An off-grid bank must carry the whole house for days without sun, whereas a hybrid bank only has to cover selected loads for the hours the grid is out.
Can the hybrid inverter charge the battery from the grid?
Most can, and it is useful for topping up before a scheduled outage or during a cloudy spell. The array still does the bulk of the charging on normal days.
Should the array be sized to the backup loads or to the whole bill?
To the whole bill. The array works like a grid-tied system during the day, so size it to your full consumption and let the backup circuit decide only the inverter and battery.
Which appliances should stay off the backup circuit?
Electric water heaters, ovens, space heaters and large air conditioners. They drain a battery quickly and force a much bigger inverter. Keep the backup circuit to the loads you genuinely cannot do without.
Is my data stored when I use this hybrid calculator?
No. The calculation runs in your browser with no signup and no storage. Close the tab and the inputs are gone.