Hybrid Solar System Size Calculator

A hybrid solar system size calculator sizes an array that feeds the house and the grid by day while a battery carries selected loads through outages or the evening. This version returns array kW, panel count and a hybrid inverter rating, and then helps you decide how much of your load belongs on the backup circuit. It is the right page for anyone who has a grid connection but cannot rely on it.

FreeNo signupNothing uploaded or stored

Your consumption

From your electricity bill. Average 12 months if you can.

Daily consumption

0.00 kWh

monthly units ÷ 30

Site and equipment

Size the array to the annual average and the battery to the essential loads and outage hours you want to cover.

Equivalent hours of full sun. See the table below.

0.78 absorbs inverter, wiring, dust and heat losses

Rating printed on the panel datasheet

Largest load that runs at the same time

1.25 leaves 25% margin for surges and heat

Battery (optional)

Sets the usable depth of discharge

Lithium ≈ 0.85, lead-acid ≈ 0.5

Hours the peak load must run from battery

Typical peak sun hours by region

Peak sun hours (PSH) are the equivalent hours per day of full 1,000 W/m² sunshine. These are rough annual averages: use a local figure or your worst month for off-grid sizing. No prices or tariffs are involved.

RegionPSH / dayNote
Pakistan (Punjab, Sindh, Balochistan)5.0 – 5.5Northern valleys and the Karachi coast are nearer 4.5 – 5
India (most states)4.5 – 5.5Lower on the monsoon coast and in the north-east
Bangladesh / Sri Lanka / Nepal plains4.0 – 5.0Dip during the monsoon months
Gulf (UAE, Saudi Arabia, Qatar, Oman)5.5 – 6.5Dust can reduce output without changing PSH
Nigeria north and middle belt5.5 – 6.0Humid south (Lagos, Port Harcourt) is 4.0 – 4.5
Kenya / East Africa5.0 – 6.0High-altitude sites are at the upper end
South Africa interior5.5 – 6.0Durban and the Cape coast are closer to 5.0
Philippines / Indonesia / Malaysia4.0 – 5.0Large seasonal dip in the rainy season
Australia (most cities)4.5 – 6.0Hobart and Melbourne are at the lower end
US Southwest5.5 – 6.5Arizona, Nevada, southern California
US Northeast / Midwest / Canada3.5 – 4.5Winter months can fall below 2.5
Southern Europe / Turkey / Egypt4.0 – 5.5Mediterranean coast
UK, Ireland, Northern Europe2.5 – 3.5Annual average; winter is much lower

Recommended array size

0.00 kW

0.00 kWh/day ÷ (4.5 h × 0.78)

Number of panels

0

550 W each → 0.00 kW installed

Inverter size

-

Enter your peak simultaneous load

Monthly production needed

0 units

0.00 kWh per day

Battery bank

0.00 kWh

0 W × 4 h ÷ 0.85 DoD

Capacity at bank voltage

0 Ah

0.00 kWh × 1,000 ÷ 48 V

Formula: array kW = daily kWh ÷ (peak sun hours × efficiency); panels = ⌈array W ÷ panel W⌉; inverter kW = peak load × 1.25; battery kWh = stored energy ÷ DoD. On-grid inverters are usually rated close to the array kW; hybrid and off-grid inverters must carry the peak load alone.

How to use the hybrid solar system size calculator

  1. Enter your average monthly units. The array is sized to the annual average because the grid still fills seasonal gaps on a hybrid system.
  2. Set peak sun hours for your area and keep the efficiency factor at its default unless you have a site survey.
  3. List the appliances you want to keep running during an outage and enter their combined watts as the peak load, since the hybrid inverter must carry that on its own.
  4. Choose a panel wattage and check the panel count against the roof, then decide how many hours of outage the battery should bridge.
  5. Read the array and inverter figures and continue to the battery calculator for the exact storage capacity.

What to include

  • Monthly units for the array size, averaged across the year
  • A short list of essential loads for the backup circuit, with their watts
  • Hours of outage per day that the battery must cover
  • Peak sun hours for the array, from the regional hint or a solar map
  • Battery chemistry, as lithium allows deeper daily cycling than lead-acid
  • Whether the inverter should charge the battery from the grid as well as from solar
  • Large loads to keep off the backup circuit, such as ovens, geysers and heaters

Hybrid sizing: the array covers the bill, the battery covers the gaps

A hybrid system has two sizing problems that are easy to confuse. The array is sized like a grid-tied system, to produce roughly the energy the house uses across the year. The battery and inverter are sized to the essential loads you want during an outage and for how long. Keeping these separate avoids the common mistake of buying an enormous battery to match a large array, or a tiny inverter that trips the moment the fridge and pump start together during a cut.

For the backup side, start with the essentials: lighting, refrigerator, internet router, a few plug points and perhaps one fan or a small air conditioner. Add their watts and that becomes the peak load the inverter must handle alone, multiplied by 1.25 for headroom. Then multiply the average draw of those loads by the outage hours to get the watt-hours the battery needs, and divide by voltage and depth of discharge. Lithium can be cycled to roughly 0.8 or 0.9 of its capacity; lead-acid to about 0.5.

When hybrid is the right choice over on-grid or off-grid

Hybrid makes sense when the grid is present but unreliable, or when you want the savings of exporting surplus by day and the comfort of backup by night. It costs more than a plain grid-tied system because of the battery and the more capable inverter, but far less than going fully off-grid, because the grid still handles bad weather and long winters. If outages are rare, on-grid is simpler. If there is no grid at all, the off-grid calculator with its autonomy-days setting is the right tool.

Frequently asked questions

Does a hybrid system need the same size battery as an off-grid one?

Usually much smaller. An off-grid bank must carry the whole house for days without sun, whereas a hybrid bank only has to cover selected loads for the hours the grid is out.

Can the hybrid inverter charge the battery from the grid?

Most can, and it is useful for topping up before a scheduled outage or during a cloudy spell. The array still does the bulk of the charging on normal days.

Should the array be sized to the backup loads or to the whole bill?

To the whole bill. The array works like a grid-tied system during the day, so size it to your full consumption and let the backup circuit decide only the inverter and battery.

Which appliances should stay off the backup circuit?

Electric water heaters, ovens, space heaters and large air conditioners. They drain a battery quickly and force a much bigger inverter. Keep the backup circuit to the loads you genuinely cannot do without.

Is my data stored when I use this hybrid calculator?

No. The calculation runs in your browser with no signup and no storage. Close the tab and the inputs are gone.