Skip to content

Solar System Size Calculator for Pakistan

This solar system size calculator for Pakistan is preset with sun-hour figures typical of the country, so you only need the units from your bill to get an array size, panel count and inverter rating. It is written for homes and small shops that face long summers, frequent load shedding and large seasonal swings in consumption. There are no tariff or price assumptions anywhere in the tool.

FreeNo signupNothing uploaded or stored

Your consumption

From your electricity bill. Average 12 months if you can.

Daily consumption

0.00 kWh

monthly units ÷ 30

Site and equipment

Most of Punjab and Sindh see roughly 5 to 5.5 peak sun hours a day. Northern and coastal areas are a little lower.

Equivalent hours of full sun. See the table below.

0.78 absorbs inverter, wiring, dust and heat losses

Rating printed on the panel datasheet

Largest load that runs at the same time

1.25 leaves 25% margin for surges and heat

Battery (optional)

Sets the usable depth of discharge

Lithium ≈ 0.85, lead-acid ≈ 0.5

Hours the peak load must run from battery

Typical peak sun hours by region

Peak sun hours (PSH) are the equivalent hours per day of full 1,000 W/m² sunshine. These are rough annual averages: use a local figure or your worst month for off-grid sizing. No prices or tariffs are involved.

RegionPSH / dayNote
Pakistan (Punjab, Sindh, Balochistan)5.0 – 5.5Northern valleys and the Karachi coast are nearer 4.5 – 5
India (most states)4.5 – 5.5Lower on the monsoon coast and in the north-east
Bangladesh / Sri Lanka / Nepal plains4.0 – 5.0Dip during the monsoon months
Gulf (UAE, Saudi Arabia, Qatar, Oman)5.5 – 6.5Dust can reduce output without changing PSH
Nigeria north and middle belt5.5 – 6.0Humid south (Lagos, Port Harcourt) is 4.0 – 4.5
Kenya / East Africa5.0 – 6.0High-altitude sites are at the upper end
South Africa interior5.5 – 6.0Durban and the Cape coast are closer to 5.0
Philippines / Indonesia / Malaysia4.0 – 5.0Large seasonal dip in the rainy season
Australia (most cities)4.5 – 6.0Hobart and Melbourne are at the lower end
US Southwest5.5 – 6.5Arizona, Nevada, southern California
US Northeast / Midwest / Canada3.5 – 4.5Winter months can fall below 2.5
Southern Europe / Turkey / Egypt4.0 – 5.5Mediterranean coast
UK, Ireland, Northern Europe2.5 – 3.5Annual average; winter is much lower

Recommended array size

0.00 kW

0.00 kWh/day ÷ (5.3 h × 0.78)

Number of panels

0

550 W each → 0.00 kW installed

Inverter size

-

Enter your peak simultaneous load

Monthly production needed

0 units

0.00 kWh per day

Battery bank

0.00 kWh

0 W × 4 h ÷ 0.85 DoD

Capacity at bank voltage

0 Ah

0.00 kWh × 1,000 ÷ 48 V

Formula: array kW = daily kWh ÷ (peak sun hours × efficiency); panels = ⌈array W ÷ panel W⌉; inverter kW = peak load × 1.25; battery kWh = stored energy ÷ DoD. On-grid inverters are usually rated close to the array kW; hybrid and off-grid inverters must carry the peak load alone.

How to use the solar system size calculator for pakistan

  1. Read the units figure from a recent bill. Use a summer and a winter bill if you can, because the difference between them in Pakistan is often large.
  2. Keep the preset peak sun hours unless you live in the far north or a coastal belt, where cloud and haze bring the figure down.
  3. Enter the watts your household draws on a summer evening, which usually means air conditioners, fans, fridge and lights running together.
  4. Choose the panel wattage you are being quoted and compare the resulting panel count with the roof area you have available.
  5. Decide whether you want on-grid, hybrid or off-grid output, since load shedding often makes hybrid the practical choice.

What to include

  • Monthly units from both a peak summer bill and a winter bill
  • Peak sun hours, roughly 5 to 5.5 for most of Punjab and Sindh
  • Number and type of air conditioners, inverter or conventional
  • Hours of load shedding you experience so backup can be planned
  • Whether the roof is a flat concrete slab or a pitched surface
  • Water pump or motor loads that have a high starting surge
  • Expected growth in consumption as the family or business expands

Sizing solar in Pakistan: strong sun, hot roofs and load shedding

Most of Punjab and Sindh see roughly 5 to 5.5 peak sun hours a day, which is generous by world standards and means a given array produces more energy than it would in much of Europe or East Asia. The catch is heat. Panels lose output as they warm up, and a flat concrete roof in Lahore or Karachi in June gets very hot. The 0.78 efficiency factor already allows for this, but mounting panels with a clear air gap underneath helps them stay closer to their rated output.

Load shedding changes the sizing question from "how many panels" to "how much of the day can I run without the grid". A pure on-grid system shuts down during an outage for safety reasons, so households that lose power for several hours a day usually look at hybrid inverters with a battery. The array size from this calculator still applies; you then add storage sized for the hours you want to cover, using the battery calculator linked below.

Flat roofs and the summer-winter gap

Flat roofs are common across Pakistani cities and are easy to work with, because panels can be tilted toward the south on simple frames without worrying about the roof pitch. Allow for walkway space, water tanks and the shadow a boundary wall throws in winter. On the consumption side, a home that uses 300 units in January might use 900 in July once the air conditioners run. Sizing to the annual average keeps the array reasonable while still covering most of the summer peak.

Frequently asked questions

What size solar system do I need for 500 units a month in Pakistan?

Type 500 into the monthly units box and the tool shows the array size instantly using the preset sun hours. The answer will differ slightly between Karachi, Lahore and Peshawar because of their sun-hour figures.

Does this calculator include net-metering rates or electricity tariffs?

No. It is a physics calculator only. Tariffs and net-metering rules change often, so you should take the kW result to your distribution company or installer for the commercial side.

Should I size for the summer bill or the winter bill?

Start with the annual average and then check the summer figure. The gap tells you how much of the array is there just for air conditioning, and you can decide how much of that peak you want to cover.

Why does the inverter suggestion come out larger than my array?

Inverter size is based on the peak load you entered, multiplied by 1.25 for headroom, not on the array. If you run three air conditioners at once, the inverter has to handle that even if daily energy use is modest.

Do I have to sign up or install anything?

No. The page runs in your browser with no account and no download. Nothing you enter is stored.