Skip to content

Generator Size Calculator

A generator that is too small trips the moment the fridge compressor kicks in, and one that is too large burns fuel running half empty. This generator size calculator adds up the running watts of the appliances you want to power, adds the starting surge you enter for motors, and applies a 25 percent margin to give a sensible rating in watts and kVA. It is free, works without an account and keeps nothing.

FreeNo signupNothing uploaded or stored

What are you sizing?

Appliances

Typical wattages (click to add)

Typical nameplate figures only. Always prefer the watts printed on your own appliance.

Sizing factors

1.25 = 25% margin for heat and motor start

VA = W ÷ PF; 0.8 is common for inverters / UPS

Used for rows without a Start W figure (motors: 2–3)

Daily energy

2.91 kWh

≈ 87 units per month (× 30)

Peak load (runs together)

985 W

985 W connected in total

Suggested generator

4.27 kVA

3,419 W = (985 W + 1,750 W largest surge) × 1.25; ÷ PF 0.8

Inverter / UPS equivalent

1,539 VA

1,231 W = peak × 1.25

Formula: daily kWh = Σ watts × qty × hours ÷ 1,000; peak W = Σ watts × qty of rows marked "On" together; inverter / UPS W = peak × 1.25, VA = W ÷ power factor; generator W = (peak + largest starting surge) × 1.25, kVA = W ÷ PF ÷ 1,000.

How to use the generator size calculator

  1. List the appliances the generator must run at once, with running watts from each nameplate and the quantity.
  2. For anything with a motor or compressor, such as a fridge, pump, air conditioner or washing machine, enter its starting surge in watts from the label or manual.
  3. Tick the items that run together. The calculator totals running watts and adds the largest surge, since motors rarely all start at the same instant.
  4. Read the suggested generator size, which is that total × 1.25, in both watts and kVA using the power factor you set.
  5. Compare the result with the continuous rating of the generators you are considering, not the peak or maximum rating on the box.

What to include

  • Running watts for every appliance on the generator circuit
  • Starting surge for each motor load, typed from the nameplate or manual
  • Which loads run together, and which you are willing to switch off while the generator is on
  • The power factor to convert watts to kVA, usually printed on the generator datasheet
  • The 1.25 margin, or more if the generator will run for long periods in hot weather
  • Whether you want the generator to also charge a battery bank, which adds the charger's draw

Starting surge: the reason generators are sized bigger than inverters

Motors draw a brief, heavy current when they start, often several times their running watts. A generator has to supply that spike without stalling, so the calculator adds the largest surge you enter on top of the running total before applying the margin. Say you type a 150 W fridge with a 600 W surge, three 75 W fans and six 10 W lights: running load is 435 W, plus the 600 W surge gives 1,035 W, and × 1.25 suggests roughly 1,300 W. A generator rated near 1.5 kVA continuous would be the one to look at.

We ask you to type the surge rather than guessing it because it varies enormously between models. The figure is usually on the nameplate as locked rotor amps or starting watts; multiply amps by volts to get watts.

Running watts, continuous rating and kVA

Generator boxes often show a peak or maximum figure that the engine can hold only briefly. Compare the calculator's result with the continuous or rated output instead. If the rating is in kVA, the calculator converts watts to kVA using the power factor you enter; many small generators quote around 0.8, but read yours from the datasheet. Running a generator at a moderate fraction of its continuous rating is usually the most fuel-efficient and the gentlest on the engine.

Frequently asked questions

What size generator do I need for a house?

Enter the appliances you will run during an outage, their surge figures, and read the suggestion. Most homes do not run everything at once on a generator, so the list is usually shorter than the full house.

How do I find the starting watts of my fridge or AC?

Check the nameplate for starting watts or locked rotor amps, or the manual. If only running watts are shown, ask the manufacturer or use a clamp meter on start-up.

Why does the calculator add only one surge, not all of them?

Because motors seldom start at the same instant. Adding every surge would oversize the generator for a situation that almost never happens. If you know two will start together, enter their combined surge.

Can a generator run a solar inverter or charge batteries?

Many hybrid inverters accept generator input. Add the charger's input watts as a row so the generator is sized to carry it alongside the house load.

Does the tool store my generator sizing?