Skip to content

AC Load Calculator (BTU and Tons to Watts)

Air conditioners are the single largest load in most hot-climate homes, and their labels speak in tons and BTU rather than watts. This AC load calculator converts the cooling capacity to a cooling figure in watts, then uses the electrical draw you read from the nameplate to give daily units and peak load for one or more units. It is free, needs no signup and stores nothing on a server.

FreeNo signupNothing uploaded or stored

What are you sizing?

Air conditioner helper

Tons and BTU/h describe cooling output, not electricity used. 1 ton ≈ 3,517 W cooling ≈ 12,000 BTU/h. Type the electrical input watts from the nameplate.

Rated running watts from the nameplate or energy label

Cooling output: 5,276 W (1.50 ton × 3,517).

Appliances

Typical wattages (click to add)

Typical nameplate figures only. Always prefer the watts printed on your own appliance.

Sizing factors

1.25 = 25% margin for heat and motor start

VA = W ÷ PF; 0.8 is common for inverters / UPS

Used for rows without a Start W figure (motors: 2–3)

Daily energy

0.00 kWh

≈ 0 units per month (× 30)

Peak load (runs together)

0 W

0 W connected in total

Suggested inverter

0 VA

0 W = 0 W × 1.25; ÷ PF 0.8

Generator (with surge)

0.00 kVA

(0 W + 0 W surge) × 1.25 ÷ PF

Formula: daily kWh = Σ watts × qty × hours ÷ 1,000; peak W = Σ watts × qty of rows marked "On" together; inverter / UPS W = peak × 1.25, VA = W ÷ power factor; generator W = (peak + largest starting surge) × 1.25, kVA = W ÷ PF ÷ 1,000. AC: 1 ton ≈ 3,517 W of cooling ≈ 12,000 BTU/h; the electrical draw comes from the nameplate.

How to use the ac load calculator (btu and tons to watts)

  1. Enter the AC's capacity in tons or BTU per hour. The tool converts between them and shows the cooling output in watts for reference.
  2. Type the electrical input watts from the nameplate or energy label. For an inverter AC use the rated running figure, not the compressor's maximum.
  3. Enter the hours per day the AC runs and the number of units, and tick whether they run at the same time.
  4. Read daily units, peak load and the suggested inverter or generator rating, then add the rest of the house on the home load page if needed.

What to include

  • Capacity in tons or BTU from the label, for the conversion
  • Electrical input watts from the nameplate, which is the number that actually matters for sizing
  • Whether it is an inverter or fixed-speed unit, since the running pattern differs
  • Realistic daily hours for the hottest month, which is what the system must cope with
  • The number of ACs and whether they run at once
  • Starting surge for a fixed-speed compressor if you are sizing a generator

Tons, BTU and watts: what the AC label actually says

A ton of cooling is 12,000 BTU per hour, which is about 3,517 W of heat removed. That is the cooling output, not the electricity consumed. The electrical input is lower because an air conditioner moves heat rather than creating it; the ratio between cooling output and electrical input is the efficiency figure on the energy label. So the tool shows the 3,517 W per ton as a conversion, but takes the actual draw from the nameplate figure you type, because that varies widely between an old fixed-speed unit and a modern inverter model.

Say you type a 1.5 ton AC: cooling output is about 5,275 W. If the nameplate says 1,300 W input and it runs 8 hours, daily energy is 10.4 units and the peak load for that one unit is 1,300 W.

Inverter AC versus fixed-speed for solar and backup

A fixed-speed AC runs its compressor at full power and cycles on and off, drawing a start-up surge every time. An inverter AC starts gently and then modulates, drawing its full rated watts only while pulling the room down to temperature and much less afterwards. For daily units, enter the rated running watts and the hours, and expect real use to be somewhat lower on an inverter unit once the room is cool. For peak load and generator sizing, the fixed-speed surge matters a lot; the inverter type needs little or no surge allowance.

Frequently asked questions

How many watts does a 1 ton AC use?

It depends on the model. One ton is about 3,517 W of cooling, but the electrical draw is what the nameplate says, and it is lower than the cooling figure. Type the nameplate input watts into the calculator.

How many units does an AC use per day?

Input watts × hours ÷ 1,000. An AC drawing 1,000 W for 8 hours uses about 8 units, and an inverter model may use less once the room is cool.

Can solar run an air conditioner?

Yes, if the array and inverter are sized for it. Take the daily units from this page to the solar system size calculator and the peak watts to the inverter size calculator.

What size generator for a 1.5 ton AC?

Enter the running watts and the starting surge from the nameplate in the generator size mode. Fixed-speed units need a considerably larger generator than inverter units of the same capacity.

Do you keep the AC details I enter?

No. The calculator runs in your browser, nothing is uploaded, and the numbers are gone when you close the page.